    <b id="fagfe"></b><bdo id="fagfe"><acronym id="fagfe"><p id="fagfe"><fieldset id="fagfe"><table id="fagfe"></table></fieldset></p></acronym><nav id="fagfe"><i id="fagfe"></i><sup id="fagfe"><mark id="fagfe"></mark><tfoot id="fagfe"></tfoot><caption id="fagfe"><abbr id="fagfe"><acronym id="fagfe"></acronym></abbr></caption><select id="fagfe"></select><link id="fagfe"></link><meter id="fagfe"><i id="fagfe"><dd id="fagfe"><textarea id="fagfe"><dt id="fagfe"></dt></textarea><td id="fagfe"></td></dd></i></meter><optgroup id="fagfe"></optgroup><ruby id="fagfe"><keygen id="fagfe"></keygen></ruby></sup></nav><rp id="fagfe"><caption id="fagfe"><select id="fagfe"><em id="fagfe"></em></select></caption></rp><input id="fagfe"></input><li id="fagfe"></li></bdo>

    <caption id="fagfe"><rt id="fagfe"><dt id="fagfe"></dt></rt></caption>

      <tbody id="fagfe"><audio id="fagfe"><li id="fagfe"></li><sup id="fagfe"><span id="fagfe"></span><figcaption id="fagfe"><span id="fagfe"><blockquote id="fagfe"></blockquote></span></figcaption><div id="fagfe"><param id="fagfe"><legend id="fagfe"></legend></param></div></sup></audio></tbody>
      <progress id="fagfe"><dfn id="fagfe"><select id="fagfe"><ins id="fagfe"><samp id="fagfe"><address id="fagfe"></address><var id="fagfe"><rp id="fagfe"></rp></var></samp></ins></select></dfn></progress>

      Today is 2019-3-27, Welcome to the web Hefei Keda Industrial Equipment Co., Ltd. Website: www.orgckn.com

      Latest information

      The whole process of intermediate frequency furnace maintenance

      Font Size: [Big][Mid][Small] 2016-8-29    Views: 418    





        Under normal circumstances, the failure of the intermediate frequency furnace can be divided into two types of failure can not be fully started and can not normally work after the start of the. As a general principle, when a fault occurs, the entire system should be fully examined in the case of a power outage, which includes the following aspects:

        (1) power supply: use a meter to measure the main circuit breaker (contactor) and control the back of the fuse if there is electricity, which will exclude the possibility of these components open circuit.

        (2) rectifier: a three-phase fully controlled bridge rectifier circuit, which includes six fast fuse, six thyristor, six pulse transformer and a diode. There is a red indicator in the fast fuse, normal indicator of shrinkage in the shell inside, when the fuse is burnt, it will pop up, some quick indicator is tight, when after fast melting, it will be stuck in the inside, so for the sake of reliability, can use the multimeter to measure a general merchandise fast fuse, to determine whether it is burnt.

        The simple method to measure the thyristor is to measure the cathode anode and the cathode resistance of the cathode with the universal resistance (200 Ohm). Under normal circumstances, the anode cathode resistance should be infinite, the gate cathode resistance should be between 50 to 10, too large or too small, it shows that the thyristor gate failure, it will not be triggered.

        The secondary side of the pulse transformer is connected with the thyristor, and the primary side is connected with the main control board. Continued flow diode is generally not prone to failure, check with a universal meter diode block test the other end, the positive time with the table shows the junction voltage drop of about 500mV, reverse No.

        (3) inverter: the inverter consists of four fast thyristor and four pulse transformer, which can be checked by the method mentioned above.

        (4): each transformer winding of the transformer should be open, the general primary resistance about tens of ohms, very few ohms. It should be noted that the original side of the intermediate frequency voltage transformer is in parallel with the load, so its resistance value is zero.

        (5) capacitors: parallel to the load of the electric heating capacitor may be breakdown, capacitors are generally installed in the condenser frame, check should be the first to determine where the breakdown capacitor. Disconnect the connection between each junction bus capacitor and main busbar, resistance measurement each capacitor two bus between the normal for infinity. After confirming the bad group, then disconnect each electric heating capacitor to lead to the bus of the soft copper, by Taiwan to find the breakdown of the capacitor. Each electric capacitor consists of four core components, the shell of a pole, the other pole are respectively led to end cover by four insulators, generally only have one core breakdown, the insulator on the trip wire, the capacitor can continue to use, the capacity of the original 3/4. Capacitor another fault is the oil spill, but generally does not affect the use, but should pay attention to fire.

        Angle mounting capacitor and a capacitor insulating frame, if the insulation breakdown will make the main circuit grounding resistance measurement between capacitor shell and capacitor lead frame, can judge the insulation condition of this part.

        (6): water cooled cable cable is connected with a frequency power and induction coil, it is each diameter 0.6 - 0.8 with the purple copper wire twisted. For 500 kg of electric furnace, the cable section area of 480 square mm, for 250 kg of electric furnace, the cable section of the use of 300 to 400 square mm. The pressure rubber tube water-cooled cable outer hose with a pressure of 5 kg, which is filled with cooling water, it is a part of the load circuit, working under tension and torsion, tilting together with furnace body and twists and turns, so after a long time to break off in the flexible connection. Water cooled cable breaking process, is generally the first to break the most, no small part soon burned at high power, the medium frequency power supply can produce very high voltage, if the voltage protection is not reliable, it will burn out the thyristor. After the water cooled cable is disconnected, the intermediate frequency power supply can not be started. If not check out the reason of repeated start, it is likely to burn out the intermediate frequency voltage transformer. Check the failure of the oscilloscope, the oscilloscope probe clip in the load at both ends, observe the start button when there is no attenuation waveform. Determine the first water-cooled cable and electric cable from the capacitor output copper bar broken core, with a multimeter resistance gear (200 block) measuring resistance value of cable, the normal resistance value is zero, off to infinity. When measuring with a universal meter, the furnace body should be turned over to the dumping position, so that the water cooled cable is dropped, so that the broken place can be completely separated, so that the core can be judged correctly.

        Through the examination of the above aspects, the general can find out most of the causes of failure, the next can be switched on to control the power supply for further inspection. The medium frequency power supply main circuit switch has two types of manual and automatic. The automatic closing system, power line should be temporarily disconnected, to ensure that the main circuit is not closed. After the power supply is switched on, the following aspects can be checked.

        1 the oscilloscope probe is connected to the gate electrode and the cathode of the rectifier thyristor. The oscilloscope is placed in the power supply. After the start button is pressed, the pulse waveform can be seen. It should be double pulse and the amplitude should be more than 2V. Click the stop button and the pulse will disappear immediately. Repeat six times, each thyristor will look at, if the gate is not a pulse, you can move the oscilloscope probe to the original edge of the pulse transformer to see if the original edge of the pulse and the second edge does not explain the pulse